TECHNICAL INFORMATION
3 all rigHts oF cHange reserVeD Part number 027650010 - Date 11/14 minimax ssP 1230, Design, installation and maintenance manual 2812 n. NorWalK, blDg 10, suite 119, mesa az 85215 / Phone 480.553.5670 Fax 480.553.5701 / salesminimaxfp.com www.minimaxfp.com. Description of the Ansul Inergen clean agent fire system and how to protect valuable, sensitive equipment. How to Install a Home Fire Sprinkler System - Duration: 8:27. Manual or Pneumatic Actuators – Three types of manual actuators. Are available for lever actuation on the cylinder valve. Manual actuation is accomplished by pulling the hand lever on the actuator. Selector Valves – Selector valves are used to direct the flow of. INERGEN agent into a single hazard of a multiple hazard system.
SYSTEM DESCRIPTION AND CONFIGURATION
The Inergen® clean agent is stored in steel cylinders with sizes up to 80 litres and 300 bar depending on the volume of the protected space(s).
The cylinders are mounted on a supporting rack inside or outside the protected space. In a multiple system, the cylinders are connected by hoses to a manifold for common distribution and discharge of the gas. The system can be released electrically or pneumatically. When the gas is released from the cylinders it passes through the nozzles which control the discharge time of the system.
The system can be installed with a common cylinder bank, a distribution manifold and valves which make it possible to protect multiple areas with one cylinder bank.
The cylinders are mounted on a supporting rack inside or outside the protected space. In a multiple system, the cylinders are connected by hoses to a manifold for common distribution and discharge of the gas. The system can be released electrically or pneumatically. When the gas is released from the cylinders it passes through the nozzles which control the discharge time of the system.
The system can be installed with a common cylinder bank, a distribution manifold and valves which make it possible to protect multiple areas with one cylinder bank.
Service & Installation - Course Details. MODULE: Stand-Alone Systems. The Control Inert (Ci) INERGEN ® system consists of the components necessary to make a complete stand-alone INERGEN ® system. The components in the Ci system are approved in accordance with current European Directives. Comprised of the iFLOW valve, the iFLOW horizontal check valve and our Matrix bracketing system, the iFLOW delivery solution works with the air in the room a.
Central system
![Installation Installation](https://5.imimg.com/data5/WR/YN/WP/SELLER-24883407/inergen-gas-refilling-500x500.jpg)
- Cylinders can be located in a centrally stored bank outside the protected space
- Distribution valves and piping are provided for each space
Modular system The breakfast club 1985 torrent download.
- Cylinders can be evenly located inside or adjacent to the protected space
- Duplicated release lines connecting the cylinders are required
Extinguishing fire using INERGEN®
Inergen Installation Manual 2017
The extinguishing principle that Inergen® uses is called oxygen displacement.
The goal of oxygen displacement is to reduce the oxygen level in a room to suffocate the fire. In the atmosphere, there is approximately 21% oxygen. The level of oxygen needed to sustain a fire varies depending on what it is that is burning, but a level below 14% oxygen will extinguish any fire in normal machinery spaces.
Inergen® systems are typically designed to reduce the oxygen level to 12%. That will extinguish the fire and at the same time be well above the level where people can breathe in the room.
The reduction of oxygen has a 3D extinguishing effect, which means that even “hidden” fires are quickly and effectively extinguished. The limited oxygen level also prevents re-ignition of the fire while cooling the room.
The goal of oxygen displacement is to reduce the oxygen level in a room to suffocate the fire. In the atmosphere, there is approximately 21% oxygen. The level of oxygen needed to sustain a fire varies depending on what it is that is burning, but a level below 14% oxygen will extinguish any fire in normal machinery spaces.
Inergen® systems are typically designed to reduce the oxygen level to 12%. That will extinguish the fire and at the same time be well above the level where people can breathe in the room.
The reduction of oxygen has a 3D extinguishing effect, which means that even “hidden” fires are quickly and effectively extinguished. The limited oxygen level also prevents re-ignition of the fire while cooling the room.
The amount of INERGEN agent to be provided shall be the amount required to obtain a uniform (minimum) concentration as required by the ANSUL INERGEN. The Ansul INERGEN Fire Suppression System protects enclosed areas where people may be present. Safe for people, INERGEN agent is.
Author: | Kigalkree Akinoktilar |
Country: | Madagascar |
Language: | English (Spanish) |
Genre: | Science |
Published (Last): | 9 March 2012 |
Pages: | 311 |
PDF File Size: | 9.69 Mb |
ePub File Size: | 3.90 Mb |
ISBN: | 887-4-38298-941-1 |
Downloads: | 25299 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Gardat |
Koetter is experienced in the installation and servicing of these complex systems provided by top-rated vendors such as: Prevent the loss of costly equipment, irreplaceable data and information as well as infrgen interruption. Simply stated, the human body is stimulated by the carbon dioxide to breathe more deeply and rapidly to compensate for the lower oxygen content of the atmosphere.
In addition to our corporate office located in Dallas Texas, KFPI has branch offices in Taiwan, Japan and China, as well as worldwide strategic partners to consistently support your global needs. It is listed and approved by governmental, nationally and internationally recognized testing laboratories.
An early warning fire detector senses minimal, invisible smoke. Ansul Inergen clean agent fire suppression systems protect enclosed areas where there is a need for quick reaction to a fire, where people may be present, where fire may strike day or night, and where damage from conventional agents cannot be tolerated.
In conjunction with manual pull stations, the system provides automatic detection, day and night.
INERGEN Fire Suppression System by Ansul
![Manual Manual](https://www.inertgasfiresystems.com/wp-content/uploads/2018/08/Impianto_Inergen_a_protezione_CED-1.jpg)
Available in four sizes, you can choose to install your cylinders either vertically or horizontally, allowing for a design that requires the fewest number of cylinders ahsul the ajsul cost. Special Fire Hazard Suppression Systems. The system is installed and serviced by authorized distributors that are trained by the manufacturer. Accessories are used ansuo provide alarms, ventilation control, door closures, or other auxiliary shutdown or functions. Because it is not a synthetic chemical, it has not been banned or restricted for use by any country.
With clean agent fire suppression, there is no agent to clean up and you are back in business faster. Fires are suppressed quickly with no residue to clean up. A system installation and maintenance manual is available containing information on system components and procedures concerning design, operation, inspection, maintenance, and recharge. After the required time delay, it energizes the cylinder electric actuator.
Ansul Inergen Clean-Agent Fire Suppression Systems
The system can be actuated by detection and control equipment for automatic system operation along with providing local and inrgen manual operation as needed. Count on Koetter Ansjl to design, install, service, inspect and maintain your fire protection systems to ensure you are always prepared. Support 24×7 You Can Count On! The cleanroom environment is unique in today’s manufacturing and the requirements for cleanli- ness, performance, and business continuity are critical to the success of any semiconductor operation.
Far cry 4 third person mod. The detection portion of the fire suppression system allows for automatic detection by means of specifically rated mechanical fusible links or electric thermal detectors. Our factory trained design experts produce engineered drawings using the latest versions of AutoCAD detailing the expected performance of your Inergen system. Advanced port scanner.
Inergen Installation Manual Pdf
Notifier, Protectowire, Cooper-Wheelock and others, that work in conjunction with your fire detection systems and equipment. Fire Suppression non-portable, specialty applications – Koetter is an authorized distributor of Amerex, Ansul, Firetrace, Pyro-Chem and other fire suppression products and systems. Best in Class Suppliers. Koetter Fire represents only the most recognized manufactures of highly specialized Fire Detection equipment like Fire Sentry, Protectowire and Vesda.
Koetter Fire’s Service Department offers hour emergency service and routine service to keep your Inergen fire system operational at all times. Additional accessories are available for shutting down electrical power to equipment and shutting down the flow of gas lines.
Protectowire Pyrochem Stat-X Vesda.
Unlike halocarbon chemical alternatives, which can create dangerous levels of hydrogen fluoride when in the presence of fire, INERGEN is entirely nontoxic, producing no corrosive decomposition products whatsoever. INERGEN agent is composed of three naturally occurring gases found in the air we breathe – nitrogen, argon and a small amount of carbon dioxide, which improves human safety.
Inergen Installation Manual Download
Once discharged, it simply returns to the atmosphere in its natural state. Koetter specializes in design and installation of CO2 fire suppression systems for the semiconductor industry asnul are recognized by Ansul as one of inerhen 10 companies in the U. Whether you need heat detectors, smoke detectors, ionization or other sophisticated infrared detectors, rely on Koetter Fire for your fire detection plan and solution. The Amerex Zone Defense Restaurant Fire Suppression System is a pre-engineered, wet chemical, stored-pressure type with a fixed nozzle agent distribution network that is fully self-contained and does not require outside water or power supply.
We specialize in design and installation of CO2 fire suppression systems for the semiconductor industry. The Ansul Inergen Fire Suppression System is a pre-engineered, stored pressure with a fixed nozzle distribution network.
As a full-service contractor, our services include a full line of portable and fixed system fire extinguishers, engineered suppression systems, fire alarm systems, sprinkler systems, emergency mass notification systems and detection and control. Fire Sentry Firetrace Kidde Notifier.
INERGEN Fire Suppression System by Ansul – BFPE International
The Stat-X fire suppressant is a patented potassium-based aerosol that suppresses fire by chemically interfering with the free radicals of flame. Koetter Fire is an authorized distributor of fire detection and suppression systems manu- factured by the biggest and best industry brand names.
In minutes, fire and the attempts to put it out can destroy the equipment that keeps your operation in action.